93 research outputs found

    Evaluation of image signal-to-noise ratio in time-of-flight PET

    Get PDF
    In PET imaging Noise Equivalent Counts (NEC) is a common image quality index, derived to be proportional to image SNR 2 and used as an index of general system performance. Many studies have shown that TOF information leads to reduced noise, faster image convergence, and improved SNR. However, the original NEC formula does not account for any contribution of timing resolution to the final image quality, and modified versions of the formula have been proposed to account for the reduction in noise variance and increased sensitivity due to TOF information. In this study, we aim to investigate the relationship between NEC and image SNR in uniform phantoms when OSEM and TOF OSEM image reconstruction is applied. Two cylindrical uniform phantoms, 20 and 35 cm in diameter, were acquired over a wide range of activity levels on a Philips Gemini TF PET scanner. Multiple realizations of the original scans were obtained through bootstrapping and reconstructed with OSEM and TOF OSEM algorithms to obtain mean and standard deviation images. The ratio of the mean value in a central ROI over both images was taken as a measure of image SNR. NEC was calculated from the original data using both the classical and a TOF-adapted formula. The results show that Trues have a better proportionality with image SNR 2 than NEC and TOF NEC in the considered range of activities. Timing resolution and Random fraction appear to have a limited influence on image SNR, but the usage of a matched TOF kernel in reconstruction is found to be necessary to maximize the gain

    Recent developments in time-of-flight PET

    Get PDF
    While the first time-of-flight (TOF)-positron emission tomography (PET) systems were already built in the early 1980s, limited clinical studies were acquired on these scanners. PET was still a research tool, and the available TOF-PET systems were experimental. Due to a combination of low stopping power and limited spatial resolution (caused by limited light output of the scintillators), these systems could not compete with bismuth germanate (BGO)-based PET scanners. Developments on TOF system were limited for about a decade but started again around 2000. The combination of fast photomultipliers, scintillators with high density, modern electronics, and faster computing power for image reconstruction have made it possible to introduce this principle in clinical TOF-PET systems. This paper reviews recent developments in system design, image reconstruction, corrections, and the potential in new applications for TOF-PET. After explaining the basic principles of time-of-flight, the difficulties in detector technology and electronics to obtain a good and stable timing resolution are shortly explained. The available clinical systems and prototypes under development are described in detail. The development of this type of PET scanner also requires modified image reconstruction with accurate modeling and correction methods. The additional dimension introduced by the time difference motivates a shift from sinogram- to listmode-based reconstruction. This reconstruction is however rather slow and therefore rebinning techniques specific for TOF data have been proposed. The main motivation for TOF-PET remains the large potential for image quality improvement and more accurate quantification for a given number of counts. The gain is related to the ratio of object size and spatial extent of the TOF kernel and is therefore particularly relevant for heavy patients, where image quality degrades significantly due to increased attenuation (low counts) and high scatter fractions. The original calculations for the gain were based on analytical methods. Recent publications for iterative reconstruction have shown that it is difficult to quantify TOF gain into one factor. The gain depends on the measured distribution, the location within the object, and the count rate. In a clinical situation, the gain can be used to either increase the standardized uptake value (SUV) or reduce the image acquisition time or administered dose. The localized nature of the TOF kernel makes it possible to utilize local tomography reconstruction or to separate emission from transmission data. The introduction of TOF also improves the joint estimation of transmission and emission images from emission data only. TOF is also interesting for new applications of PET-like isotopes with low branching ratio for positron fraction. The local nature also reduces the need for fine angular sampling, which makes TOF interesting for limited angle situations like breast PET and online dose imaging in proton or hadron therapy. The aim of this review is to introduce the reader in an educational way into the topic of TOF-PET and to give an overview of the benefits and new opportunities in using this additional information

    Design of a static full-ring multi-pinhole collimator for brain SPECT

    Get PDF
    In clinical practice, brain SPECT is mostly performed using a dual-head SPECT scanner with fan-beam or parallel-beam collimators rotating around the patient's head. The resolution of such a system is typically about 6-8 mm, which is rather poor to image the complex structures of the human brain. We developed a non-rotating multi-pinhole collimator for brain SPECT imaging with a resolution of 4 mm. A full-ring geometry allows for complete transaxial sampling. This enables the use of a stationary collimator. The collimator is a tungsten ring with two rows of pinholes. Each pinhole can individually be opened or closed with shutters. A sequence of shutter movements is performed to obtain an acquisition setup that simulates a rotational movement. The collimator is designed for the LaPET system (a PET detector ring made of 24 LaBr 3 detectors) and is optimized to maximize the system performance, resulting in a collimator radius of 145 mm and a pinhole diameter of 2 mm. This system has a sensitivity that is 4 times lower than a dual-head system with LEHR parallel-beam collimators. However, the resolution is 2 times better, a trade-off that is supported by Muehllehner [1]. Monte-Carlo simulated projections of a resolution phantom are successfully reconstructed and the resulting image shows that a resolution of 4 mm is indeed achieved

    A 64-pixel Positron-Sensitive Surgical Probe

    Get PDF
    We report on the continued development of a 64-pixel positron-sensitive surgical probe with a dual-layer detector and multi-anode PMT. An 8 x 8 array of this plastic scintillators in teh first layer detects positrons and a matched GSO crystal array in the second layer detects annihilation 511 keV gammas, which are required to be in coincidence with the detected positrons. Also, the 64 PMT anode signals are differentiated and an overshoot threshold is applied to separate the fast decay plastic anode signals from the slower GSO signals. Finally, an energy threshold is applied to the summed anode signal to distinguish 511 keV gammas from the 140 keV gammas commonly used in sentinel lymph node (SLN) surgery. Previously we reported on how these signal selection criteria were individually tested and optimized based on 9 channels of prototype electronics [1-2]. Currently the electronics shave been upgraded to Xilinx® programmable components, allowing on-the-fly alteration of signal selection criteria, and all 64 channels are operational. Initial measurements of the complete 64-pixel probe were conducted using 18F-FDG positron sources and 18F-FDG and 99mTcphantoms (background 511 keV and 140 keV gammas), simulating lesions in the SLN surgery environment. The average positron sensitivity is measured to be 3.0-7.0 kcps/µCi at different signal selection criteria. The lower bound on sensitivity corresponds to settings optimized for high image resolution and high background rejection ability. The upper bound on sensitivity corresponds to settings optimized for high sensitivity at the cost of lower image resolution and lower background rejection ability. The measured true-to-background contrast in the presence of clinically observed levels of 511 keV and 140 keV background gammas is ~3:1 for a tumor-to-background uptake ratio of 5:1. Performance measurements of the complete 64-pixel probe including sensitivity, true-to-background ratio, and the pixel separation ability are presented

    Walk-through flat panel total-body PET: a patient-centered design for high throughput imaging at lower cost using DOI-capable high-resolution monolithic detectors.

    Get PDF
    PURPOSE Long axial field-of-view (LAFOV) systems have a much higher sensitivity than standard axial field-of-view (SAFOV) PET systems for imaging the torso or full body, which allows faster and/or lower dose imaging. Despite its very high sensitivity, current total-body PET (TB-PET) throughput is limited by patient handling (positioning on the bed) and often a shortage of available personnel. This factor, combined with high system costs, makes it hard to justify the implementation of these systems for many academic and nearly all routine nuclear medicine departments. We, therefore, propose a novel, cost-effective, dual flat panel TB-PET system for patients in upright standing positions to avoid the time-consuming positioning on a PET-CT table; the walk-through (WT) TB-PET. We describe a patient-centered, flat panel PET design that offers very efficient patient throughput and uses monolithic detectors (with BGO or LYSO) with depth-of-interaction (DOI) capabilities and high intrinsic spatial resolution. We compare system sensitivity, component costs, and patient throughput of the proposed WT-TB-PET to a SAFOV (= 26 cm) and a LAFOV (= 106 cm) LSO PET systems. METHODS Patient width, height (= top head to start of thighs) and depth (= distance from the bed to front of patient) were derived from 40 randomly selected PET-CT scans to define the design dimensions of the WT-TB-PET. We compare this new PET system to the commercially available Siemens Biograph Vision 600 (SAFOV) and Siemens Quadra (LAFOV) PET-CT in terms of component costs, system sensitivity, and patient throughput. System cost comparison was based on estimating the cost of the two main components in the PET system (Silicon Photomultipliers (SiPMs) and scintillators). Sensitivity values were determined using Gate Monte Carlo simulations. Patient throughput times (including CT and scout scan, patient positioning on bed and transfer) were recorded for 1 day on a Siemens Vision 600 PET. These timing values were then used to estimate the expected patient throughput (assuming an equal patient radiotracer injected activity to patients and considering differences in system sensitivity and time-of-flight information) for WT-TB-PET, SAFOV and LAFOV PET. RESULTS The WT-TB-PET is composed of two flat panels; each is 70 cm wide and 106 cm high, with a 50-cm gap between both panels. These design dimensions were justified by the patient sizes measured from the 40 random PET-CT scans. Each panel consists of 14 × 20 monolithic BGO detector blocks that are 50 × 50 × 16 mm in size and are coupled to a readout with 6 × 6 mm SiPMs arrays. For the WT-TB-PET, the detector surface is reduced by a factor of 1.9 and the scintillator volume by a factor of 2.2 compared to LAFOV PET systems, while demonstrating comparable sensitivity and much better uniform spatial resolution (< 2 mm in all directions over the FOV). The estimated component cost for the WT-TB-PET is 3.3 × lower than that of a 106 cm LAFOV system and only 20% higher than the PET component costs of a SAFOV. The estimated maximum number of patients scanned on a standard 8-h working day increases from 28 (for SAFOV) to 53-60 (for LAFOV in limited/full acceptance) to 87 (for the WT-TB-PET). By scanning faster (more patients), the amount of ordered activity per patient can be reduced drastically: the WT-TB-PET requires 66% less ordered activity per patient than a SAFOV. CONCLUSIONS We propose a monolithic BGO or LYSO-based WT-TB-PET system with DOI measurements that departs from the classical patient positioning on a table and allows patients to stand upright between two flat panels. The WT-TB-PET system provides a solution to achieve a much lower cost TB-PET approaching the cost of a SAFOV system. High patient throughput is increased by fast patient positioning between two vertical flat panel detectors of high sensitivity. High spatial resolution (< 2 mm) uniform over the FOV is obtained by using DOI-capable monolithic scintillators

    Fault Tolerance in Protein Interaction Networks: Stable Bipartite Subgraphs and Redundant Pathways

    Get PDF
    As increasing amounts of high-throughput data for the yeast interactome become available, more system-wide properties are uncovered. One interesting question concerns the fault tolerance of protein interaction networks: whether there exist alternative pathways that can perform some required function if a gene essential to the main mechanism is defective, absent or suppressed. A signature pattern for redundant pathways is the BPM (between-pathway model) motif, introduced by Kelley and Ideker. Past methods proposed to search the yeast interactome for BPM motifs have had several important limitations. First, they have been driven heuristically by local greedy searches, which can lead to the inclusion of extra genes that may not belong in the motif; second, they have been validated solely by functional coherence of the putative pathways using GO enrichment, making it difficult to evaluate putative BPMs in the absence of already known biological annotation. We introduce stable bipartite subgraphs, and show they form a clean and efficient way of generating meaningful BPMs which naturally discard extra genes included by local greedy methods. We show by GO enrichment measures that our BPM set outperforms previous work, covering more known complexes and functional pathways. Perhaps most importantly, since our BPMs are initially generated by examining the genetic-interaction network only, the location of edges in the protein-protein physical interaction network can then be used to statistically validate each candidate BPM, even with sparse GO annotation (or none at all). We uncover some interesting biological examples of previously unknown putative redundant pathways in such areas as vesicle-mediated transport and DNA repair

    TGF-β-Mediated Sustained ERK1/2 Activity Promotes the Inhibition of Intracellular Growth of Mycobacterium avium in Epithelioid Cells Surrogates

    Get PDF
    Transforming growth factor beta (TGF-β) has been implicated in the pathogenesis of several diseases including infection with intracellular pathogens such as the Mycobacterium avium complex. Infection of macrophages with M. avium induces TGF-β production and neutralization of this cytokine has been associated with decreased intracellular bacterial growth. We have previously demonstrated that epithelioid cell surrogates (ECs) derived from primary murine peritoneal macrophages through a process of differentiation induced by IL-4 overlap several features of epithelioid cells found in granulomas. In contrast to undifferentiated macrophages, ECs produce larger amounts of TGF-β and inhibit the intracellular growth of M. avium. Here we asked whether the levels of TGF-β produced by ECs are sufficient to induce a self-sustaining autocrine TGF-β signaling controlling mycobacterial replication in infected-cells. We showed that while exogenous addition of increased concentration of TGF-β to infected-macrophages counteracted M. avium replication, pharmacological blockage of TGF-β receptor kinase activity with SB-431542 augmented bacterial load in infected-ECs. Moreover, the levels of TGF-β produced by ECs correlated with high and sustained levels of ERK1/2 activity. Inhibition of ERK1/2 activity with U0126 increased M. avium replication in infected-cells, suggesting that modulation of intracellular bacterial growth is dependent on the activation of ERK1/2. Interestingly, blockage of TGF-β receptor kinase activity with SB-431542 in infected-ECs inhibited ERK1/2 activity, enhanced intracellular M. avium burden and these effects were followed by a severe decrease in TGF-β production. In summary, our findings indicate that the amplitude of TGF-β signaling coordinates the strength and duration of ERK1/2 activity that is determinant for the control of intracellular mycobacterial growth

    A quantitative analysis of complexity of human pathogen-specific CD4 T cell responses in healthy M. tuberculosis infected South Africans

    Get PDF
    Author Summary: Human pathogen-specific immune responses are tremendously complex and the techniques to study them ever expanding. There is an urgent need for a quantitative analysis and better understanding of pathogen-specific immune responses. Mycobacterium tuberculosis (Mtb) is one of the leading causes of mortality due to an infectious agent worldwide. Here, we were able to quantify the Mtb-specific response in healthy individuals with Mtb infection from South Africa. The response is highly diverse and 66 epitopes are required to capture 80% of the total reactivity. Our study also show that the majority of the identified epitopes are restricted by multiple HLA alleles. Thus, technical advances are required to capture and characterize the complete pathogen-specific response. This study demonstrates further that the approach combining identified epitopes into "megapools" allows capturing a large fraction of the total reactivity. This suggests that this technique is generally applicable to the characterization of immunity to other complex pathogens. Together, our data provide for the first time a quantitative analysis of the complex pathogen-specific T cell response and provide a new understanding of human infections in a natural infection setting

    Transancestral mapping and genetic load in systemic lupus erythematosus

    Get PDF
    Systemic lupus erythematosus (SLE) is an autoimmune disease with marked gender and ethnic disparities. We report a large transancestral association study of SLE using Immunochip genotype data from 27,574 individuals of European (EA), African (AA) and Hispanic Amerindian (HA) ancestry. We identify 58 distinct non-HLA regions in EA, 9 in AA and 16 in HA (B50% of these regions have multiple independent associations); these include 24 novel SLE regions (Po5 10 8), refined association signals in established regions, extended associations to additional ancestries, and a disentangled complex HLA multigenic effect. The risk allele count (genetic load) exhibits an accelerating pattern of SLE risk, leading us to posit a cumulative hit hypothesis for autoimmune disease. Comparing results across the three ancestries identifies both ancestry-dependent and ancestry-independent contributions to SLE risk. Our results are consistent with the unique and complex histories of the populations sampled, and collectively help clarify the genetic architecture and ethnic disparities in SL

    SARS-CoV-2 susceptibility and COVID-19 disease severity are associated with genetic variants affecting gene expression in a variety of tissues

    Get PDF
    Variability in SARS-CoV-2 susceptibility and COVID-19 disease severity between individuals is partly due to genetic factors. Here, we identify 4 genomic loci with suggestive associations for SARS-CoV-2 susceptibility and 19 for COVID-19 disease severity. Four of these 23 loci likely have an ethnicity-specific component. Genome-wide association study (GWAS) signals in 11 loci colocalize with expression quantitative trait loci (eQTLs) associated with the expression of 20 genes in 62 tissues/cell types (range: 1:43 tissues/gene), including lung, brain, heart, muscle, and skin as well as the digestive system and immune system. We perform genetic fine mapping to compute 99% credible SNP sets, which identify 10 GWAS loci that have eight or fewer SNPs in the credible set, including three loci with one single likely causal SNP. Our study suggests that the diverse symptoms and disease severity of COVID-19 observed between individuals is associated with variants across the genome, affecting gene expression levels in a wide variety of tissue types
    corecore